Air flow sensor SFAH-50U-Q8S-PNLK-PNVBA-M8 8058472
| Product description | Area of application | Functions | IO-Link |
| The flow sensor SFAH is suitable for | Process monitoring | Monitoring using the teach-in | Serial communication integrated |
| monitoring compressed air and noncorrosive gases. The sensor can be | Handling of extremely small parts | function or by entering values | using IO-Link® 1.1 |
| used in many industry segments | Monitoring of compressed air | Mass flow rate and volumetric flow | Cyclical transfer of two switching |
| thanks to its compact design. The | consumption | rate are displayed in the common | states and the measured flow value |
| method of measurement is based on | Leak test | measurement units | Remote parameterisation of the |
| the thermal heat-transfer method. The | Monitoring of forming gas | ECO function with option to switch | sensor is possible using an |
| bypass construction means that it is | Pneumatic object detection via | off the display | IO-Link® master |
| less susceptible to disruption by | air-gap measurement | Optional security code can be freely | Easy sensor replacement with |
| particles and moisture. The flow value | Monitoring and setting a flow rate | chosen (4-digit code) | automatic parameterisation |
| is transmitted to the connected control system as a switching signal, as | threshold, a flow rate range or a | Adjustable low-pass filter for | Sensor identification, diagnostics |
| an analogue signal or via IO-Link®. | change in flow rate | smoothing the flow signal | and teach-in possible via IO-Link® |
| Scaling the analogue output to | |||
| increase the signal dynamics | |||
| Offset compensation possible | |||
| Min./max. value memory | |||
| All settings that have been entered | |||
| on one sensor (master) can be | |||
| transferred (replicated) to other, | |||
| identical sensors | |||
| High pressure range –0.9 bar to | |||
| 10 bar |